Features TS's Products
 

Oscillator:                                                                                A current controlled, state-variable true sine wave oscillator incorporating a fast AGC circuit. Distortion components are typically 0.1% 2nd and 0.05% 3rd which are low order and not audible making the TS1 & TS2 useful in making listening tests where a function generator would generate undesirable, audible side effects. Full frequency sweeps can be made from 20Hz - 20kHz in a single range. These units have no amplitude changes over the entire frequency range

 

Frequency Counter:                                                                   The frequency counter is internally connected to the internal oscillator and displays the oscillator frequency until a signal is plugged into the input connector. It then displays the frequency of the input signal. This unique combination allows absolute precision in setting frequencies.

 

dB Meter:                                                                                  The dB meter is a wideband average responding AC voltmeter. The circuit output is converted to dB for display. Direct reading dB greatly simplifies alignment procedures.

 
Battery Pack Option:
A sealed, maintenance free, Gel-type rechargeable battery mounted in a metal enclosure on the rear panel of the test set. (Factory installed only).
Volts: 12Vdc nominal
Capacity @20 Hr rate: 1.2 AH nominal
Discharge current @20 Hr rate: 60mA nominal
Recharging: Battery is automatically recharged whenever the unit is plugged into AC power and the AC power switch is on.
Size (W x H x D); Weight: 4" x 2" x 2"; 1.4 lbs.
 
Impedance Meter:

The impedance meter measures complex impedance in ohms. It allows the user to set up and validate studio equipment, measure components, develope equipment, test loudspeakers and enclosures and to measure and validate distributed loudspeaker systems.