Features SLC1
SPL Meter Trigger a Relay |
|
The Controls: |
Set: The set control is provided to specify the maximum
allowable sound level.
SPL Weight: Measurements can be made in SPL FLAT, A, or
C.
|
|
The
Response Control: A potentiometer
is provided to determine how quickly the SLC1 will respond to a
signal that exceeds the specified level. At minimum the SLC1 is
most sensitive and will respond quickly to a small amount of
overage. As the control is advanced, it will take longer to
respond to the same amount of overage but will respond more
quickly to a larger overage. At maximum the SLC1 will take a
while to respond to a small overage but will respond relatively
quickly to a large overage |
|
Recovery
Control: This control has been pre-set by the factory
to cover most situations. A cap has been placed over the
control. For special applications the customer can remove the
cap and re-set this control. The recovery control determines how
quickly the SLC1 responds to occasional bursts that exceed the
specified level. At minimum the SLC1 will ignore short duration
bursts that exceed the specified sound level. As the control is
advanced, the SLC1 will retain the effect of shorts bursts
longer resulting in a more sensitive response. At maximum the
unit will be factoring in any overages regardless of duration.
|
|
Reset
Delay Control: The reset control sets the time interval
after the relay is triggered before it will allow the relay to
trigger again. The minimum interval is approximately 10 seconds
and the maximum interval approximately 120 seconds. |
|
|